Product Details - Exterior Grade Stairs Example
The following are a number of examples of ways to use Ply-Lam for exterior grade stairs. While some dimensions are provided as guidelines, these examples are not intended as a complete engineered design. Please ensure that you always follow appropriate engineering rules and building code guidelines when constructing stairs.
The below diagram and chart shows engineered Unsupported Stringer Lengths for PT Ply-Lam as an Eastern (or Cut-Out) Stringer.
In the below diagram and chart, the Thickness (W) and Effective Depth (ED) of the stringer are adjusted based on the required unsupported length.
The chart below uses the above indices and shows the Alberta Building Code Permitted Unsupported Length. All measurements are given in Inches:
Product Code |
Thickness (Width - W) |
Effective Depth (ED) |
AB Code Permitted Unsupported Length |
PT PL4 C 4.625 | 1.5 | 4.625 |
80 (We recommend a maximum of 6 steps) |
PT PL4 C 8.625 | 1.5 | 8.625 |
148 (We recommend a maximum of 11 steps) |
PT PL8 C 4.625 | 3 | 4.625 |
101 (We recommend a maximum of 8 steps) |
PT PL8 C 8.625 | 3 | 8.625 |
188 (We recommend a maximum of 15 steps) |